Climate controller for mushroom growing chambers MR-2560_Z-90

The power supply voltage of the device is DC 6 ... 24V
The current consumed by the device, taking into account the current of the drives controlled by the device, up to 3 A
Temperature measurement inputs - 1 input
Number of connected temperature sensors - 12 sensors are implemented, as many as possible 16 sensors
Type of temperature sensors to connect - DS18B20
The maximum length of the temperature sensor cable is 50 meters
Analog inputs 0 ... 10 V measurement of CO2 concentration - 1 input
Type of connected CO2 sensors - with analog output voltage 0 ... 10 V
The maximum length of the CO2 sensor cable is 200 meters
Analog inputs of the device 0 ... 10 V - 6 inputs with resistance 100 kOhm
Analog outputs with voltage 0 ... 10V - 6 outputs. The input resistance of the connected device is not less than 100 kOhm. Protected against short circuit
Outputs for connecting relays with an operating voltage of 24 V, winding current up to 40 mA - 6 outputs
Communication interfaces RS485 - 2 interfaces. Used to connect the device with a computer, with a modem, with far-located sensors (up to 500 meters)
The location of the terminals for connecting external devices - inside the case under the removable front panel
Terminal pitch - 3.5 mm
Type of conductor to be connected - copper, one wire up to 1 mm in diameter
Screen device - monochrome LCD 4 lines of 20 characters
Keyboard - 4 button, button layout
Dimensions: height - 175 mm (without taking into account the height of the seal), width - 225 mm, depth - 80 mm