The climatic controller for chambers of cultivation of mushrooms MR-1284_Z-58

The power supply voltage of the device is DC 24V
The current consumed by the device, taking into account the current of the drives controlled by the device, up to 1.5 A
Temperature measurement inputs - 2 inputs
Number of connected temperature sensors - 12 sensors are implemented, as many as possible 16 sensors
Type of temperature sensors to connect - DS18B20
The maximum length of the temperature sensor cable is 50 meters
Analog inputs 0 ... 10 V measurement of CO2 concentration - 1 input
Type of connected CO2 sensors - with analog output voltage 0 ... 10 V
The maximum length of the CO2 sensor cable is 200 meters
Analog inputs of the device 0 ... 10 V - 6 inputs with resistance 100 kOhm
Analog outputs with voltage 0 ... 10V - 6 outputs. The input resistance of the connected device is not less than 10 kOhm
Outputs for connecting relays with an operating voltage of 24 V, winding current up to 40 mA - 6 outputs
Communication interfaces RS485 - 2 interfaces. Used to connect the device to the computer, with far-located sensors (up to 500 meters)
Interface for connecting an external keyboard - 5-wire, MR
Interface for connecting an external screen - 4-wire, MR
The location of the terminals for connecting external devices - along the long sides of the rear part of the housing
Terminal pitch - 3.5 mm
Type of conductor to be connected - copper monofilament with a diameter of up to 1 mm
Screen device - monochrome LCD 4 lines of 20 characters
Keyboard - 4 button, button arrangement in-line
Dimensions: height - 80 mm, width - 155 mm, depth - 55 mm